Bog Standard Plumbing and Heating
Our Services

Central Heating Installation

Gas Safe registered engineers designing and fitting complete central heating systems, from heat-loss surveys to zoning and controls.

About This Service

Central heating designed around your home

Bog Standard Plumbing and Heating carries out central heating installation in Brierley Hill and nearby, from upgrading an old system to fitting new heating with pipework throughout. Using Worcester Bosch and Baxi systems, Megaflo unvented cylinders and industry-grade pipework, our Gas Safe registered engineers fit and commission whole-home heating to manufacturer standards.

We're heating engineers based in Brierley Hill, serving Cradley Heath, Halesowen and Stourbridge and the surrounding area.

If you only need a new boiler, see our gas boiler installation service instead.

Central heating designed around your home
Our Process

How It Works

01

Site survey and heat-loss calculation

We carry out a room-by-room heat-loss survey, measure radiators and assess pipe routes to produce a system design and parts list.

02

Equipment selection and install

We install approved boilers, Megaflo cylinders, radiators and pipework, then fit zoning valves and advanced controls where required.

03

Commissioning and handover

System is flushed where needed, pressures set, controls programmed and safety checks completed. You receive operating guidance and paperwork for warranties.

Benefits

What you can count on with a new system

Premium kit, installed to standard

Worcester Bosch and Baxi systems, Megaflo cylinders and BPEC Unvented G3 compliant work preserve manufacturer warranties and improve efficiency.

Local, responsive engineers

We're a local team, with no call-out fee for surveys and diagnostics. You can see the towns and villages we cover on our areas we cover page.

Whole-system approach

From heat-loss surveys and radiator sizing to zoning and smart controls, installations are designed to reduce cold spots and control running costs.

Combi, system or regular boiler?

  • Combi boiler. Heats water as you use it, with no tank or cylinder. Suits most homes with one bathroom, though the flow drops if two hot taps run at once.

  • System boiler. Stores hot water in a cylinder, usually at mains pressure. Suits homes with two or more bathrooms, but needs space for the cylinder.

  • Regular boiler. Works with a cold water tank in the loft and a hot water cylinder. Often the right choice in older homes with low mains water pressure.

At the survey we check your bathrooms, water pressure and space, then recommend the type that fits. Our guide to the different types of boiler explains more. Off mains gas, an oil boiler can run your heating instead, and we're OFTEC registered for oil work.

What a new central heating system costs

We price every installation from the survey, because these make the biggest difference:

  • The size of your home. More rooms means more radiators and pipework.

  • Replacement or first-time. Reusing existing pipework is quicker than piping a house that has never had central heating.

  • Your floors. Pipes run quickly under timber floorboards. Solid concrete floors take longer.

  • The boiler and hot water. A combi needs no cylinder. A system or regular boiler does.

  • Zoning and controls. Separately controlled zones add valves and thermostats.

  • What can be kept. Radiators and pipes in good condition can sometimes stay after a power flush.

What happens each day

A typical installation runs in this order:

  • Day one. The old system is drained and the old boiler and radiators come out. Your heating is off from here, and with a combi so is your hot water.

  • The middle days. New pipework goes in, floorboards are lifted and relaid, and the boiler, radiators and any cylinder are fitted.

  • The last day. The system is filled, flushed and protected with inhibitor, safety checks are done, the controls are set up and we show you how it all works.

The paperwork you get at the end

A new boiler is notifiable building work. As a Gas Safe registered business, we notify your council through the Gas Safe Register, and a Building Regulations Compliance Certificate is posted to you a few weeks later. You'll need it when you sell.

You should also receive:

  • the Benchmark commissioning checklist, filled in and signed

  • the manufacturer's warranty registration. Its length depends on the boiler, and most makers ask for a yearly service to keep it valid

  • the commissioning record for an unvented cylinder, if one is fitted

What our customers say

Bog Standard Plumbing and Heating is rated 4.9 out of 5 on Google. Here's what two customers said about their heating:

"Recently had all my radiators etc changed ,first class job done by Ronnie as always.Been using this company for a few years now never had a problem. Always polite &courteous, would recommend to anyone." - Anita, Google

"Great service and a fantastic install. seems ashamed to cover up such nicely done pipework! thanks" - Tom, Facebook

FAQ

Frequently Asked Questions

Times vary by property size and scope. As a general guide, replacing the boiler and radiators in a typical three-bedroom semi takes two to four working days, and a first-time installation with new pipework throughout takes three to five days or more. We give a clear programme after the site survey.

A correctly sized boiler, properly balanced radiators and smart controls will usually improve efficiency and comfort. Savings depend on existing kit condition, insulation and user habits. Our heat-loss survey and system design aim to optimise running costs as well as comfort.

Yes. Our team are Megaflo installers and BPEC Unvented G3 trained, so we design and fit unvented cylinders to the correct regs. We size cylinders to your hot water demand and commission expansion and safety controls as required.

Zoning divides a property into independently controlled areas using motorised valves and thermostats, reducing wasted heat. We fit programmable and smart controls that integrate with boiler manufacturers so you get accurate room temperatures and better system efficiency. See our smart heating controls page.

Often, yes. Radiators that heat evenly, aren't leaking or badly corroded, and are big enough for the room once the heat-loss survey is done can usually stay. A power flush clears out sludge before the new boiler goes in, and building rules ask for thermostatic valves on most radiators when a boiler is replaced. Radiators that are undersized or failing are worth replacing while the system is drained.

A home that has never had mains gas needs a gas connection before a gas boiler can be fitted. You apply to the gas network company (Cadent in the West Midlands) to lay a pipe to your house, then an energy supplier fits the meter. This can take several weeks, so start early. If mains gas isn't practical, an oil boiler is the usual alternative.

Arrange a central heating site survey

Book a survey and design meeting with our Gas Safe engineers. There's no call-out fee for the survey.